Wolcott Chimney Contractors

What the camera saw, and what fixes it

Get the repair priced

Reading the footage

Clay tile was the standard lining for brick chimneys through most of the last century. Each section is roughly two feet tall, stacked end on end with mortar at the joints. On camera a sound flue looks even from bottom to top, and every finding that fails an inspection shows up as a break in that pattern.

We describe each break in the report by height and side, with a still from the footage, so the person deciding on the repair can see what we saw.

  • A vertical crack through one or more tiles, common after a quake or a chimney fire
  • Joints with the mortar fallen out, letting smoke and heat reach the brick
  • A tile shifted sideways off the one below it
  • Broken pieces of tile lying on the smoke shelf
  • No tile at all, which we still find in some of the oldest houses

The usual fixes

Relining is the most common answer. A stainless steel liner runs from the top of the chimney down to the fireplace or the appliance, gets insulation where the space allows, and ends under a cap. When the old tile is only cracked it can stay where it is behind the new liner. A cast-in-place liner is another option on some chimneys, but it fills the old flue and suits fewer of them.

When the damage sits in the top few tiles and the brick around them has gone loose as well, rebuilding that part of the stack with new tile can be the better buy. When the owner wants heat more than an open fire, a gas insert with its own liner retires the old flue entirely.

What carries a published price

Relining, partial rebuilds and smoke chamber work vary too much from one chimney to the next for a list price: the height of the stack, the size of the flue, any bend in the run and how hard the roof is to work all change the labor. We write one figure for each once we have the footage.

A failed flue often comes with a second problem at the top: no cap, so rain has been washing out the joints, or water getting in where the chimney meets the roof. Those repeat from roof to roof with less variation, so they carry published ranges.

Prices for the usual follow-on fixes

Ranges follow the size of the flue and the roof. Your written estimate names one figure.

Gas insert that retires the old flue
$2,850 to $5,700
Finding and stopping water at the stack
$570 to $3,400
Saddle to split runoff behind a wide stack
$455 to $1,030
Saddle built in with the roof metal renewed
$685 to $1,700
Follow-up camera run after relining
$400
Top cover over a relined or bare flue
Quoted after we measure

Relining, partial rebuilds and smoke chamber repairs are not on this list; each gets a written figure from the footage.

Owners with a failed flue ask

Can a cracked clay tile be patched?

Open joints can sometimes be resurfaced, but a tile cracked through is usually lined over instead, because a patch deep inside a flue is hard to prove sound on camera.

Does a fireplace that burns gas logs need a sound flue?

Yes. Gas exhaust carries a lot of water vapor, which condenses in a cold masonry flue and works on the joints. A gas insert also needs a liner sized to it.

Will relining change how the fireplace draws?

A liner sized to the opening usually draws better than a cracked, oversized clay flue. On a very large old opening, the liner that fits the chimney may be too small for an open fire, and we say so before you commit.

Will a buyer or insurer want proof of the repair?

Often. A follow-up camera run shows the new liner in place from bottom to top, and it is listed in the prices above.

Why is there no relining price on this page?

The cost follows your chimney: stack height, flue size, bends in the run and roof access. We write the figure once we have the footage in hand.

Holding a report that failed the flue?

Send the findings from the contact page and we reply with the repair we would suggest and how it is priced.

Call (323) 521-4624